Türkiye EchoSpec 1108 Phased Array Ultrasonic Testing System
Built on an open-platform architecture, the EchoSpec 1108 PAUT System allows custom-tailored solutions. With compact footprint and simple assembly, it supports high-channel configurations and delivers ultra-high-speed PAUT and FMC/TFM inspection.
Category:
TürkiyePhased Array Series
Product Description
Built on an open-platform architecture, the EchoSpec 1108 PAUT System allows custom-tailored solutions. With compact footprint and simple assembly, it supports high-channel configurations and delivers ultra-high-speed PAUT and FMC/TFM inspection.
* System
| Configuration | 16/16,16/64,16/128.16/256,32/32,32/128,32/256,64/64,64/128,64/256 | |||
| Ultrasonic mode | Pulse echo, one transmission, one reception, through (TT) | |||
| Full matrix acquisition | Support, all FMC technologies are compatible | |||
| Weight | Less than 2Kg | |||
| Temperature sensor | Yes | |||
| Open source SDK | Yes (complete documentation API) | |||
| Software development language | C++, Python, C #, LabVIEW, MATLAB, etc | |||
| Operating System | Windows,Linux | |||
| AFM-API | Includes TFM, real-time acquisition imaging (optional) | |||
* Pulse generator
| Voltage | 100V (multiplex) adjustable 25~100V (non multiplex) | |||
| Pulse generator | Negative square wave | |||
| Pulse width | 30~1000ns (optional lower frequency) | |||
| Pulse width resolution | 4 ns | |||
| Range of Launch Delay | 0-40 μs | |||
| Launch delay accuracy | 4 ns | |||
| Maximum PRF | 20 kHz | |||
* Receiver
| Sampling precision | 14 bits per channel | |||
| Gain range | 110 dB | |||
| System bandwidth | 0.3~20MHz(Optional 50kHz) | |||
| Receiving delay range | 0~40us,(At a sampling rate of 100MHz) | |||
| Receiving delay accuracy | 5 ns | |||
| DDF | 64 points | |||
* Data Processing
| FIR filter | 64-tap | |||
| Filter coefficient | 15, customizable by users | |||
| A-scan resolution | 8bit,16bit | |||
| Digital frequency | 100 MHz | |||
| Downsampling | 50.33.25.16.65.14.28.12.5MHz | |||
| A-scan compression | Support | |||
| Full record of A-scan data | Support | |||
| The number of data points scanned by A | 4096 points in FMC mode, 32K in PAUT mode | |||
| The number of focusing rules | 4096 | |||
| Gate | 4 (wave amplitude, transit time) | |||
| Gate mode | Any (peak, Flank, zero point before crossing the gate, zero point after crossing the gate) | |||
| IF gate | Support (interface wave or bottom wave tracking) | |||
* Communication
| Communication link | LAN(TCP protocol, Gigabit Ethernet) | |||
| Effective ultrasound data transmission rate | 100 MB/S | |||
* Input and Output
| Encoder | X. Y (differential, unipolar) | |||
| Encoder Mode | Orthogonal, orthogonal edges, direction, upward, downward | |||
| Synchronous input | Pulse trigger, sequence trigger, encoder | |||
| Synchronous output | Pulse trigger, sequence trigger | |||
| Pin assignment | programmable | |||
| Number of input/output ports | 8 | |||